Alignment is easily accomplished with an optical sight and a twodigit signal strength meter incorporated into the beam detector. Notifier s intelliquad plus detector is a plugin, addressable device that provides both fire and carbon monoxide co detection. Beam200, beam200s singleended reflected type projected beam smoke detector specifications general range. Mar 19, 2014 chapter 3 of the reflected beam smoke detector video series includes stepbystep instructions for both the coarse alignment and fine adjustment processes. Beam200, beam200s singleended reflected type projected. Fsb 200a and fsb200sa singleended, reflectortype addressable beam smoke detector jci60189. If point annunciation 192 intelligent aim 200 points and 56 standard system circuits of a single aim 200 is desired, the aim 200 must be mounted in the second slot. Ideal applications include warehouses, atriums, aircraft hangers, sporting arenas and concert halls. The fsb200 and fsb200s are a transmitterreceiver unitand a reflector. Notifier recommends spacing detectors in compliance with nfpa 72. C general the johnson controls fsb200 and fsb200s are intelligent, addressable reflected beam smoke detectors for protecting open areas with high and sloping ceilings, and wideopen areas, where spottype smoke detectors are difficult to install.
The fsb200 and fsb200s are a transmitterreceiver unit and a reflector. It is uniquely suited for protecting large open areas with high ceilings, where spottype smoke detectors are difficult to install and maintain. This manual should be left with the owneruser of this equipment. Jul 25, 2018 how to video for nfxi beam detectors installation and alignment. Notifiers intelligent and addressable fsb200 series is the indus trys most reliable smoke sensing technology for high and.
Beamlrk long range kit for use with reflective projected beam. Model fsb 200 fsb 200s is a long range projected beam smoke detector designed to provide open area protection. For fire, the detector combines four separate sensing elements in one unit smoke, co, infrared, and heat to sense multiple components of a fire. If point annunciation 192 intelligent aim200 points and 56 standard system circuits of a single aim200 is desired, the aim200 must be mounted in the second slot. View and download system sensor fsb 200 installation and maintenance instructions manual online. Ideal applications are atriums, cathedral ceilings, aircraft hangers, warehouses, sporting are. The nfxi beam is entirely loop powered without the need of a separate local power supply.
Sep 22, 2016 bosch power tools ds240 users manual hochiki europe uk ltd spc manualzz sheet e85001 0560 reflective beam detector using the mounting bracke fireray 50r 100r ffe beam detectors installation instructions. Fsb200a200sa intelligent beam smoke detector with flashscan. Fsb200, fsb200s singleended reflected type projected beam. Beam detectors system sensor beam detectors distributor.
The notifier fsb 200s is an intelligent projected beam smoke detector with integral sensitivity test filter requires external power supply. Singleended reflected type projected beam smoke detector. This manual is available online at general description system sensor model beam200beam200s is a long range projected beam smoke detector designed to provide open area protection. Notifier nfs23030 intelligent addressable fire alarm system. System sensor linear heat detector lhd dealers in chennai india. From apartments buildings to industrial buildings, manufacturing plants and more, notifier makes alarms to suit the needs of nearly any building. Please thoroughly read this manual and applicable sections of system sensors singleended reflected beam detector application guide bmag240. Fsb200a and fsb200sa singleended, reflectortype addressable beam smoke detector. Beam200, beam200s singleended reflected type projected beam. Providing fast, reliable response to fires and superior immunity to false alarms, combined with greater efficiency and low cost of ownership. The notifier fsb200 and fsb200s are intelligent, addressable reflected beam smoke detectors for protecting open areas with high and sloping ceilings, and. Notifier by honeywell is known for providing stateoftheart fire alarm systems with installations on every continent. Notifier also manufactures digital voice command for mass notification systems.
Life safety consultants stocks a wide range of notifier parts, including hard to find notifier pull stations and even discontinued notifier smoke alarm parts. Please thoroughly read this manual and applicable sections of system sensors manual i56506, guide for proper use of projected beam detectors. The fsb 200s consists of a transmitter receiver unit and a reflector. The notifier fsb 200 and fsb 200s are intelligent, addressable reflected beam smoke detectors for protecting open areas with high and sloping ceilings, and wideopen areas, where spottype smoke detectors are difficult to install and maintain. The fsb 200s is a singleended beam smoke detector with integral sensitivity test for use with onyx series panels. A ifc640 shown in cab4 with jnca 640character display general as a standalone smalltolarge system, or as a large network, the ifc640 meets virtually every application requirement. The system sensor fsb200 and fsb200s are intelligent, addressable projected beam smoke detectors for protecting open areas with high and sloping ceilings, and wideopen areas, where spottype smoke detectors are difficult to install and maintain. Copies of this manual are available from system sensor. Intelligent beam smoke detector with integral sensitivitytest. Notifier by honeywell is a manufacturer of fire protection products such as afp2800, afp3030 addressable fire alarm panels, smoke detectors and evacuation systems. Compatible for use with all notifier intelligent fire alarm control panels.
Chapter 3 of the reflected beam smoke detector video series includes stepbystep instructions for both the coarse alignment and fine. The detector consists of a transmitterreceiver unit and a reflector. Notifier archives page 4 of 7 fire alarm resources. Notifier frm1 relay module notifier fsb200 series reflected beam. The notifier fsb200 is an intelligent projected beam smoke detector. Fsb200 series intelligent beam detectors honeywell. The fsb 200 is a singleended beam smoke detector for use with onyx series panels. Distributor channel partner of beam detectors system sensor beam detectors, reflected beam detectors, fireray 5000 motorized reflective type beam detector and morley ias mi lpb beam detector offered by fire projects private limited, ahmedabad, gujarat. Fsb200, fsb200s singleended reflected type notifier. It operates primarily on the principle of light obscuration utilising infrared light. The fsb200s consists of a transmitter receiver unit and a reflector.
Smoke entering the area between the transmitter receiver and reflector causes a reduction in signal. Fsb 200 a and fsb 200sa singleended, reflectortype addressable beam smoke detector isox fault isolator module intelligent bases standard, relay, isolator, sounder, and lowfrequency sounder bases. Risco rwx74 wireless two way beam detector user manual. The nfxibeam is entirely loop powered without the need of a separate local power supply. Output voltage is the same as device input voltage. Fsb200a and fsb200sa singleended, reflectortype addressable beam smoke detector isox fault isolator module intelligent bases standard, relay. Notifier s full range of intelligent sensors and advanced detection products form part of a range which makes a notifier system one of the most capable, flexible and comprehensive available. Ifc640 intelligent addressable fire alarm system jci6856. Chapter 3 of the reflected beam smoke detector video series includes stepby step instructions for both the coarse alignment and fine. View details of beam 2imports shipment data to india with price, date, hs. The infrared transmitter generates a beam of light towards a high efficiency reflect. The fsb200 consists of a transmitter receiver unit and a reflector.
Beamlrk long range kit for use with reflective projected. The notifier fsb200s is an intelligent projected beam smoke detector with integral sensitivity test filter requires external power supply. Beam smoke detector as2100 special detectors notifier. The beam1224 is a 4wire, singleended, reflected type beam smoke detector that includes an 8 reflector. The system sensor fsb200 and fsb200s are intelli gent, addressable projected beam smoke detectors for pro tecting open areas with high and sloping ceilings, and wide open areas, where spottype smoke detectors are difficult. Notifiers intelliquad plus detector is a plugin, addressable device that provides both fire and carbon monoxide co detection.
Notifier inteksecurity access control system fire alarm system. Reflected beam smoke detectors are designed for spacious rooms, open areas, and high ceilings. View and download notifier fsb200 user manual online. Ifc640 intelligent addressable fire alarm system catalog page. The fsb200 is a singleended beam smoke detector for use with onyx series panels. Listed for operation from 22f to 1f, the fsb200 and fsb200s are usable in open area applications where temperature extremes exceed the design limits of other types of smoke detection. Notifier afp3030 intelligent fire alarm control panel notifier annunciator modules. How to video for nfxi beam detectors installation and alignment.
The opal addressable beam detector is an intelligent reflector type linear optical beam smoke detector designed to operate with notifier addressable fire alarm systems. Long range accessory kit required for applications in excess of 230 ft70 m. The notifier fsb200 and fsb200s are intelligent, addressable reflected beam smoke detectors for protecting open areas with high and sloping ceilings, and wideopen. Do not mount the beam detector on corrugated metal walls, sheet metal walls, external building sheathing, external siding. The notifier fsb200 and fsb200s are intelligent, addressable reflected beam smoke detectors for protecting open areas with high and sloping. Ideal applications include warehouses, atriums, aircraft hangers, sporting arenas and.
System sensor beam 200 and beam200s needs to installed qualified engineer. General description system sensor model beam200abeam200sa is a long range projected beam smoke detector designed to provide open area protection. Notifiers full range of intelligent sensors and advanced detection products form part of a range which makes a notifier system one of the most capable, flexible and comprehensive available. Visual and audible evacuation alerts simultaneously alert and dispatch first responders through networked monitoring services. The system sensor beam1224 and beam1224s are 4wire conventional projected beam smoke detectors. The osirifl is a intelligent addressable reflectortype linear optical beam smoke detector. Intelligent beam smoke detector with integral sensi tivity test. The notifier fsb200 and fsb200s are intelligent, addressable reflected beam smoke detectors for protecting open areas with high and sloping ceilings, and wideopen areas, where spottype smoke detectors are difficult to install and maintain. Notifier by honeywell datasheets addressable systems. Notifier archives page 4 of 7 fire alarm resources free. It is to be used with ul listed compatible fire alarm control panels only. Beam smoke detector, composed of a transmitter and a receiver. System sensor beam1224 type beam smoke detector new inbox description.
Fsp 851a series detectors are compatible with notifier onyx and clip series. Model fsb200fsb200s is a long range projected beam smoke detector designed to provide open area protection. Fsd751pl and fsd751rpl intelligent lowflow photoelectric duct with. Distributor channel partner of a wide range of products which include system sensor beam detectors, reflected beam detectors, fireray 5000 motorized reflective type beam detector, morley ias mi lpb beam detector, fire ray infrared beam detector and fire ray beam detector. Automatic gain dusty compensation for loss of signal. Notifiers fully integrated addressable fire alarm systems detect gas, smoke or fire with sensitive detection equipment right down to the exact location of the source, pinpointing the room and floor the fire started in. Chapter 3 of the reflected beam smoke detector video series includes stepbystep instructions for both the coarse alignment and fine adjustment processes. Singleended, reflectedtype addressable beam smoke detectors. Notifier manufactures ewis systems, occupant warning and speakers.
The fsb200s is a singleended beam smoke detector with integral sensitivity test for use with onyx series panels. Long range kit for use with reflective projected beam smoke detectors 3825 ohio avenue, st. The notifier fsb200 and fsb200s are intelligent, addressable reflected beam smoke detectors for protecting. View and download notifier fsb 200 user manual online. Detector placement this section of the manual discusses the placement of projected beam detec. Fsb200a singleended, reflectedtype addressable beam. Model fsb200 fsb200s is a long range projected beam smoke detector designed to provide open area protection. It is to be used with ulclisted compatible control panels only. Notifier nfxibeam loop powered beam detector the opal addressable beam detector is an intelligent reflector type linear optical beam smoke detector designed to operate with notifier addressable fire alarm systems.
They are uniquely suited for protecting open areas with high ceilings where intelligent spot type smoke detectors are difficult to install and maintain. Adjustment of beam intensity based on distance through trimer. View and download system sensor fsb200 installation and maintenance instructions manual online. Notifier downloadable data sheets, instructions, manuals, and other pdfs. It is to be used with ullisted compatible control panels only. Is one of the leader companies at the middle east region, egypt, and north africa acting as one stop shop in the.